Siemens SINAMICS G130 Engineering Manual page 301

Sinamics - low voltage sinamics drives
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

SINAMICS G130
Line supply voltage
400 V / 500 V / 690 V
With one motor reactor
380 V – 480 V 3AC
500 V – 600 V 3AC
660 V – 690 V 3AC
With dv/dt filter plus VPL
380 V – 480 V 3AC
500 V – 600 V 3AC
660 V – 690 V 3AC
With dv/dt filter compact plus VPL
380 V – 480 V 3AC
500 V – 600 V 3AC
660 V – 690 V 3AC
With sine-wave filter
380 V – 480 V 3AC
500 V – 600 V 3AC
Permissible motor cable lengths for SINAMICS G130 (continued)
When two motor reactors are connected in series, the permissible cable lengths can be increased even further to
450 m with shielded cables and 675 m with unshielded cables.
Rated power at
e.g. Protodur NYCWY
110 kW - 560 kW
110 kW - 560 kW
75 kW - 800 kW
110 kW - 560 kW
110 kW - 560 kW
75 kW - 800 kW
110 kW - 560 kW
110 kW - 560 kW
75 kW - 800 kW
110 kW - 250 kW
110 kW - 132 kW
Maximum permissible motor cable length
Shielded cable
300 m
300 m
300 m
300 m
300 m
300 m
100 m
100 m
100 m
300 m
300 m
SINAMICS Engineering Manual – November 2015
SINAMICS G130
Engineering Information
Unshielded cable
e.g. Protodur NYY
450 m
450 m
450 m
450 m
450 m
450 m
150 m
150 m
150 m
450 m
450 m
301/528
Ó Siemens AG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g150Sinamics s120Sinamics s150

Table of Contents