IP 266
Encoder direction of rotation
The direction in which the encoder revolves is ascertained from the encoder's two
signals, which are displaced from each other by 90 deg.
A
B
Signal A leading
90°
Figure 5-1. Encoder Signal Evaluation
5.1.3

Traversing Range

Software limit switches (linear axis only)
The software limit switches are used to define the traversing range of your drive.
In a fully configured drive system, the software limit switches define the internal
boundaries of the traversing range.
Start of
machine
N
H
S
A
A
N
/N
: Emergency limit switches start/end
A
E
(power section)
H
/H
: Hardware limit switches start/end
A
E
S
/S
: Software limit switches start/end
A
E
Figure 5-2. Linear Axis with Range Limit Switches (not to scale)
EWA 4NEB 812 6057-02
Machine Data, Modes and Traversing Programs
The direction changes at this point
Table
A
Traversing range
Signal B leading
End of
machine
S
H
N
E
E
E
Deceleration distance S
Clearance distance X
t
Br
5-7