Enable Teach-In (Mode 10) - Siemens SIMATIC S5 Manual

Ip 266 positioning module
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

Machine Data, Modes and Traversing Programs

5.3.10 Enable Teach-In (Mode 10)

Enable teach-in
Program number
Mode
This mode is used to create a new traversing program for
automatic mode
automatic single block mode
Prerequisites to the use of this mode:
The new traversing program must be assigned a number that has not already
been assigned to another program.
The IP 266's RAM must contain valid machine data.
The reference point must be set.
There must be enough room in the IP 266's RAM for the new program.
Enter a program number that is not yet on the module. A traversing program
with this number is then generated on the IP 266.
Each block in the new program has the same structure, and comprises three ele-
ments:
Block number
Target position
Speed
Block number
The blocks are numbered (see Section 5.4) in ascending order, beginning with
N01. The third block thus has the number N03.
5-46
Start
Parameters
Function
IP 266
EWA 4NEB 812 6057-02