IP 266
Function key menu:
<F1>
Press this key to screen the next page of the "INPUT MACHINEDATA"
form. This function is possible only when you have filled in all input
fields correctly.
<F2>
Use this key to screen the preceding page of the "INPUT MACHINE-
DATA" form. This function is possible only when you have filled in all
input fields correctly.
<F4>
Press this key to start a printout.
<F6>
Once you have filled in all input fields, you can press this key to store
the machine data on the specified destination device.
The data destination is shown in the header.
Data stored on the IP 266 is first verified. Errors are flagged on the
error line. When an error is detected, the page of the "INPUT
MACHINEDATA" form in which the error was made is displayed on the
monitor.
<F7>
Use this key to choose the values for 'Meas.System' and 'Axis type'.
<F8>
After confirming your intention to exit by responding to the relevant
prompt with <F1>, this key returns you to the "FUNCTION SELECT"
menu.
With the exception of <F7>, the function key menu is the same for all seven
pages of the "INPUT MACHINEDATA" form. <F7> is included in the function key
menu on pages 1, 3 and 7 only.
And what now?
Enter 11 (the same number entered in the "PRESETS" form) in the 'Module'
field.
Set the cursor to the input field for 'Meas.System' and make your selection
with <F7>. The default value for this field in [mm].
Move the cursor to 'Axis type' and select the linear axis with <F7>. The word
'LINEAR' is displayed in the input field.
Press <F1> to screen the second page of the "INPUT MACHINEDATA" form.