Machine Data, Modes and Traversing Programs
Example 1:
An incremental encoder generates 1000 pulses
per revolution. During this time, the reference
point on the axis travels a distance of 5 mm.
The resolution is thus:
Example 2:
In your drive system, you are using an encoder that generates 1000 pulses per
revolution. You are using a rotary axis, and have initialized it in [deg]. During one
encoder revolution, the drive moves 10 degrees.
Based on these values, the encoder resolution computes to the following:
10 deg
A =
1000 pul
A=
0.01 deg/pul
A=
10 · 0.001 deg/pul
Example 3:
The table below lists a number of examples of permissible and impermissible
parameter values:
Travel per revolution
Unit
1 mm
[µm]
200 deg
[0.001 deg]
40 deg
[0.001 deg]
10 in
[0.0001 in]
100 in
[0.0001 in]
5-6
A =
A =
Pulses per
Resolution
revolution
µm
[
5000
0.200
0.001 deg
[
1000
200
0.001 deg
[
500
80
0.0001 in
[
1800
55.56
0.0001 in
[
2000
500
IP 266
5 mm
1000 pul
µ
5
m/pul
Permissible
Unit
/
]
pul
/
]
pul
/
]
pul
/
]
pul
/
]
pul
EWA 4NEB 812 6057-02