Fundamentals of COM 266
Data area:
Field name
Type
Actual value,
O
These fields show the actual values that were on screen at the instant at
distance to go,
which the mode was changed.
following error
Aux. function
O
The last M function activated is displayed in this field, or "255" if no M
functions were invoked (in the PLC: KH format="FF", KF format="1").
M02 is output following termination of a traversing (machining)
program.
Mode
I
Enter the number of the required mode in this field. The mode number
must be in the range from 1 to 19. The mode identification text is
displayed at the right of this number. Press <F7> to screen a list of all
modes (1 to 19).
The display for mode 5 differs from that of the other modes in that an
additional input field is provided at the right of the mode identification
text; using <F7>, you can set this field to either "set" or "approach".
Program
I
Enter the number of a traversing (machining) program in this field for
modes 8, 9 and 10.
Distance
I
An entry must be made in this field for modes which require a distance
specification for an absolute or relative positioning operation, a zero
offset or a tool offset.
Override
I
The speed for a positioning operation can be modified by entering an
override factor in this field (for modes 1 to 7). The positioning speed can
also be altered during traversing. The override factor must be forwarded
to the IP with <F6>.
"Type" column: I = input field, O = output field