Siemens SIMATIC S5 Manual page 196

Ip 266 positioning module
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

IP 266
Data area for a rotary axis:
If you are using the IP 266 to operate a rotary axis, the two fields for the software
limit switches are replaced by fields for
• the start of the traversing (machining) range and
• the end of the traversing (machining) range
Field name
Type
Module
Meas.System
O
Refer to the data area on page 2
Axis type
Ref. point
I
The reference point coordinate must lie within the traversing
coordinate
(machining) range or at exactly the upper or lower limit of that range.
Start of tra-
I
This value specifies the start of the traversing (machining) range for the
versing (machi-
rotary axis, and must be lower than the value specifying the end of the
ning) range
traversing (machining) range.
End of tra-
I
This value specifies the end of the traversing (machining) range for the
versing (machi-
rotary axis, and must be higher than the value specifying the start of the
ning) range
traversing (machining) range.
Tool length
I
See the table entitled 'Data Area for a Linear Axis'
offset
"Type" column: I = input field, O = output field
Function key menu:
The function key menu is identical to that for page 2 of "INPUT MACHINEDATA".
And what now?
Fill in all input fields on this page.
Press <F1> to screen page 5 of "INPUT MACHINEDATA".