Tait TB8100 Service Manual page 264

Hide thumbs Also See for TB8100:
Table of Contents

Advertisement

Reprogramming
and Recalibration
264
Power Management Unit Card and Board Replacement
If you have replaced the HVDC and microprocessor card, you will have to
reprogram the PMU as described in the table below.
Procedure
reprogram the product code
reprogram the serial number
a. To reprogram this information into the PMU, you will need to use a dongle with the
Calibration Kit.
If you have changed the configuration of the PMU by fitting or removing a
standby power supply card, you will have to reprogram the PMU as
described in the following table.
Procedure
reprogram the product code
a. To reprogram this information into the PMU, you will need to use a dongle with the
Calibration Kit.
There is no need for any recalibration when any of the plug-in cards is fitted,
removed or replaced.
Details
reprogram this information into the PMU
a
using the Calibration Kit
Calibration Kit documentation for more
details
Details
use the Calibration Kit to reprogram the
PMU with the product code which
corresponds to the new configuration of the
a
PMU
; for more details refer to
the PMU" on page
217, and to the
Calibration Kit documentation