Table 8.4
Placement of the input coupling components according to frequency band
5W
Band
C109
C110
B
C
H
K
R138/
R145/
R139
R146
L
Table 8.5
Test point voltages on the LPF/directional coupler board
Test Point
Pin Name
TP101
FWD-PWR-ANA
TP102
REV-PWR-ANA
TP103
+10V
TP104
LPF-DC-ROM
(OR to ground)
TP105
GND
a. Measured when the PA is set to its rated RF output power (i.e. 5W, 50W, or 100W according to model).
TB8100 Service Manual
© Tait Electronics Limited September 2006
50W
100W
C109
C110
C109
R138/
R145/
R138/
R139
R146
R139
Tx Off
Tx On
Voltage
Voltage
0.27V
>0.27V
0.27V
<0.5V
10V
10V
0V
0V
100W +
Isolator
C110
C109
C110
R145/
R138/
R145/
R146
R139
R146
a
Notes
analogue voltage, proportional to
forward power
analogue voltage, proportional to
reverse power
regulated 10V to bias the directional
coupler diodes
the microprocessor senses this input to
verify the presence of the LPF/
directional coupler board
ground
Power Amplifier Fault Finding
Component Type
IPN 018-11820-10 CAP
0603 8p2 50V NPO ±0.1pF
IPN 018-11820-10 CAP
0603 8p2 50V NPO ±0.1pF
IPN 018-11330-10 CAP
0603 3p3 50V NPO ±0.1pF
IPN 015-21100-05 CAP cer
1p0 ±0.1pF 200V 0805
IPN 036-10000-00 RES
0805 0R 1/8W