Task 2 —
Check Resistance of
PFC and HVDC FETs
Task 3 —
Check Operation of
Soft-Start Relay
242
Power Management Unit Fault Finding
1.
If you have not already done so, remove the covers and end panels,
then disconnect the AC module from the DC module, as described
in
"Power Management Unit Disassembly and Reassembly" on
page
249.
2.
Check the AC module board and cards for any visible signs of
damage.
Important
Make sure the AC module is disconnected from any power
source before testing the FETs. Wait for five minutes for the
internal voltages to self-discharge before testing.
3.
Check that the in-circuit gate-to-source resistance of the FETs is as
follows (refer to
HVDC FETs (Q201, Q202):
PFC FETs (Q305, Q306):
If the resistance is correct, go to
module and go to
4.
Check that the drain-to-source resistance of the HVDC FETs is
approximately 300kΩ.
If the resistance is correct, go to
module and go to
1.
Remove the standard PFC control card and fit the modified card in
its place (refer to
2.
Set up the test equipment as shown in
power supplies to 0V (or off), and make sure the load (if used) is
disconnected.
3.
Slowly increase the control input voltage. You should hear the relay
click at approximately 8VDC. PFC gate drive starts at 16.5VDC to
17VDC. If the relay clicks, set the control input voltage to 15VDC
and go to
Task
"Final Tasks" on page
Figure
13.10):
approximately 4k6Ω
approximately 3M3Ω..
Step
"Final Tasks" on page
Task
"Final Tasks" on page
"Modifying the PFC Control Card" on page
4. If it does not, replace the AC module and go to
247.
© Tait Electronics Limited September 2006
4. If it is not, replace the AC
247.
3. If it is not, replace the AC
247.
Figure
13.11. Set the DC
TB8100 Service Manual
246).