How to start and terminate your work
Variant 2 - partial switch-off in case of an emergency stop
Conveyors, conveyor line* and X-ray generators are switched off immediately when an emergency stop but-
ton is pressed, the electronics and monitors of the X-ray units remain switched on.
Possibly, the following window or other error message appears:
If neither the illustrated window nor any other error message appears after an emergency stop button
was actuated, press the
diately when resetting the emergency stop state!
After you have eliminated the safety risk reset the emergency stop button by turning or pulling (F 1-94).
In older units the power supply for the conveyors and X-ray generators will be thus restored automatic-
ally.
In newer units, however, you have to briefly turn the key switch on the keyboard of the X-ray unit to the
right to position II (clearing the emergency stop state and restoring the power supply for conveyors an X-
ray generators).
Delete possibly existing error messages with
After a short while you can restart the conveyors.
How to log in
If a login procedure has been selected for the HI-SCAN X-ray unit, the window for entering your User ID will
be displayed on the screen.
Login via ISIS card*
If the X-ray unit is equipped with ISIS* (Intelligent Screener Identification System), you can or have to log in
with your ISIS card.
1-34
1
key first. Doing so, you avoid that the conveyors possibly start running imme-
r
.
95587412 01/01/09 © Smiths Heimann