Other operating troubles

Other operating troubles
The following operating troubles may occur if you are logged in as supervisor.

The TIP or OTS system* does not work correctly

Cause
The TIP system inserts threat objects for operators
only, but not for supervisors.
You selected threat image categories which do not
contain any images or which contain deactivated im-
ages only.
The selecting percentage is set to 0% for all threat
image categories.

A removable drive* does not work

Cause
The drive is not inserted correctly.

A USB memory* does not work

Cause
The USB memory is not inserted correctly.

Error messages and error report

Except for the error messages listed in section 1 (para-
graph "Operating troubles - error messages"), the follow-
ing other may occur:
2-92
Correction
 To test the TIP parameters, log in as operator.
 Check the selected categories and activate a suf-
ficient number of images, if necessary (F 2-55 or
2-68).
 For one or several categories, set a selecting per-
centage of altogether 100% (F 2-52 or 2-66).
Correction
 Check if the release trigger of the drive has
locked and if the LED on the drive lights up
shortly when switching on the unit (F 2-4).
Correction
 Check the connection (F 2-8).
I
Unlike users with lower access level you
can copy all error messages collected as
yet in the error report to a ZIP disk*, a
CD* or a USB memory*.