How to correct operating troubles
When selecting certain image displays and/or the Zoom function, the con-
veyors stop
This is no error. Higher access level users can determine not to use certain image display modes as long as
the conveyors are running. As a result, the conveyors will stop automatically when selecting such display
modes and such display modes will be switched off when starting the conveyors.

A warning signal is sounded

(Baggage marking was not actuated)
Cause
Single sound:
Someone has put a hand into the tunnel or an item
has been shifted or thrown into the tunnel while the
conveyors were standing.
Periodical sounds or permanent sound at simultan-
eous power failure
Periodical sounds or permanent sound without
simultaneous power failure:
The power fail buffer* of the X-ray unit signalizes an
internal error.

Other errors

 You should ask your local service office or Smiths Heimann to do the repair. To localize error causes, you
should indicate the data of the configuration display (F 1-92) and the error codes (Error report F 1-93).
1-106
Correction
 Ensure that nobody puts hands into the tunnel.
Reverse the conveyors to check if items have been
thrown into the tunnel.
 See paragraph "Power failure" (F 1-94).
S
Attention!
The X-ray unit will switch off itself very soon!
 If the X-ray unit has not been connected to the
mains for some time, the batteries of the power
fail buffer have been possibly discharged . Con-
nect the unit to the mains for at least 12 hours to
recharge the batteries. Afterwards you can use
the X-ray unit again. When you keep the unit con-
stantly connected to the mains, even if the unit is
not used, you ensure that the batteries remain
charged.
 If the X-ray unit has been connected to the mains
or if the error cannot be eliminated by recharging
the batteries, the power fail buffer needs to be re-
paired.