xStatus UserInterface Extensions Widget [n] WidgetId

Returns the unique identifier for a widget. Widgets are used in custom panels, for example
in-room controls, that are added to the user interface.
Requires user role: ADMIN, INTEGRATOR, USER, ROOMCONTROL
Value space of the result returned:
String
D15335.08 Cisco TelePresence MX700 and MX800 API Reference Guide CE9.2, NOVEMBER 2017.
About the API
xConfiguration
xCommand

Video status

xStatus Video ActiveSpeaker PIPPosition

Shows the position of the active speaker's image on the screen.
Requires user role: ADMIN, INTEGRATOR, USER
Value space of the result returned:
UpperLeft/UpperCenter/UpperRight/CenterLeft/CenterRight/LowerLeft/LowerRight
Example:
xStatus Video ActiveSpeaker PIPPosition
*s Video PIP ActiveSpeaker Position: UpperCenter
** end

xStatus Video Input Connector [n] Connected

Shows whether is something is connected to the specified connector. Not all connections can
be detected.
Requires user role: ADMIN, INTEGRATOR, USER
Value space of the result returned:
False/True/Unknown
Example:
xStatus Video Input Connector 1 Connected
*s Video Input Connector 1 Connected: True