Cisco TelePresence MX700 and MX800
Introduction

SystemUnit status

xStatus SystemUnit Hardware Module CompatibilityLevel

The Cisco TelePresence endpoints are using a NAND flash memory for general storage. The
endpoints running TC software are manufactured with a new version of the flash memory.
Endpoints having the new version of the flash memory must run software TC4.2.1 or later. Some
previous TC software versions are updated to support the new flash memory. Please check the
release note to find if the new version of the flash memory is supported. If your endpoint does
not have the CompatibilityLevel command it does not have the new flash memory installed.
The result returned when running the command is either 0 or 1:
0 = The system does not have the new flash memory installed.
1 = The system has the new flash memory installed. If downgraded, it can only be downgraded
to previous TC software versions having support for the new version of the flash memory.
Requires user role: ADMIN, USER
Value space of the result returned:
1/0
Example:
xStatus SystemUnit Hardware Module CompatibilityLevel
*s SystemUnit Hardware Module CompatibilityLevel: 1
** end

xStatus SystemUnit Hardware Module SerialNumber

Shows the serial number of the hardware module in the codec.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Module SerialNumber
*s SystemUnit Hardware Module SerialNumber: "FTT123456A1"
** end
D15335.08 Cisco TelePresence MX700 and MX800 API Reference Guide CE9.2, NOVEMBER 2017.
About the API
xConfiguration
xCommand

xStatus SystemUnit Hardware Monitoring Fan [n] Status

The feedback shows the speed (rpm) for the specified fan.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Monitoring Fan 1 Status
*s SystemUnit Hardware Monitoring Fan 1 Status: "locked on 1096 rpm"
** end

xStatus SystemUnit Hardware Temperature

Shows the current maximum temperature (degree Celsius) measured in the codec/system.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Temperature
*s SystemUnit Hardware Temperature: "64.0"
** end

xStatus SystemUnit Notifications Notification [n] Text

Lists text related to important system notifications. Notifications are issued e.g. when a system
was rebooted because of a software upgrade, or when a factory reset has been performed.
All the notifications can be removed from the list by issuing the xCommand SystemUnit
Notifications RemoveAll command.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit Notifications Notification 1 Text
*s SystemUnit Notifications Notification 1 Text: "OK"
** end