Pollen Filter - Cleaning - Case 570T Operator's Manual

Hide thumbs Also See for 570T:
Table of Contents

Advertisement

Pollen filter - Cleaning

1. Follow Machine safety position. (Refer Engine - Safety
rules).
2. Before servicing the pollen filter located under the oper-
ator's seat, switch off the blower and close all windows
and one door.
ATTENTION: In humid conditions, do not switch on the
blower prior to servicing the pollen filter. Damp particles
drawn into the filter may solidify and prove difficult to re-
move without washing.
3. Forcibly close the other door. The resulting back pres-
sure will dislodge the loose dirt from the underside of
the pollen filter.
4. Remove the two clips (2) from the sides and remove
the cover (1) from below the seat.
5. Pull out the pollen filter (3) straight.
ATTENTION: The filter elements are made of specially
treated paper with a sealing strip bonded to the outer face.
So make sure that the filter element and the sealing faces
are not damaged on removal.
6. Clean the pollen filter by blowing with the compressed
air from the clean side through to the dirty side with a
pressure lower than 2 bar (29 psi).
7. Install the pollen filter and close the cover.
7 - MAINTENANCE
7-64
1
PTIL14TLB0063AB
2
PTIL14TLB0064AB