Transmission suction strainer - Cleaning

1. Follow Machine safety position. (Refer Engine - Safety
rules)
2. Remove the cap screws (2) from transmission assem-
bly (1).
3. Remove the screen cover (3).
4. Remove the strainer (4) and O-ring (5).
5. Clean the strainer using dry compressed air.
6. Install the strainer (4) and O-ring (5).
7. Install the screen cover and cap screws.