Procedure 3-6. Power-Up (Continued)
Step
25.
Ports 5001, 5002, 5003 and 5004 on the TimeSource 3600 are used as though they were
serial TL1 communication ports. The following values are set at the factory and appear at
reset:
MONMSG – INH (monitors only the current port for messages)
KEEPALIVE = 0 – does not send a COMPLD message to keep connection open)
ENDOFTEXT = 0 – does not include an end-of-text code with a TL1 message)
ECHO = ALW – (echoes characters back to the sending terminal)
COMPRI = ALW1 – (normal communication, including autonomous messages)
AUTOLOGOFF = 20 – (does not log off the user during inactivity)
SWCONTROL = INH – (uses no flow control)
If these values require change, use the Edit Communications command to set
communications parameters for TL1 communications.
ED-COM::COM-a:<ctag>:::[MONMSG=b[,]][KEEPALIVE=c[,]]
[ENDOFTEXT=d[,]][ECHO=b[,]][COMPRI=e[,]][AUTOLOGOFF=c[,]]
[SWCONTROL=b];
COM-a – User IP port (a = 5001, 5002, 5003 or 5004)
MONMSG=b – Monitors messages on all ports (b = ALW), or current port (b = INH)
KEEPALIVE=c – Inactive minutes until the unit sends a COMPLD message to keep the
connection from being closed (c = 0 to 255)
ENDOFTEXT=d – Hex code added to responses before semicolon (d = 0 (disabled) to 9F)
ECHO=b – Echoes characters received so they appear on the user's screen as typed
(b = ALW), or inhibits echo (b = INH)
COMPRI=e – Sets the communication port capabilities as follows:
ALW0 = normal communication, no autonomous messages
ALW1 = normal communication, autonomous messages
ALW2 = autonomous messages received, logged on or not
INH = closes connection and keeps port from use (command must go to
another port) (if the port is in use, this command also logs off the user)
AUTOLOGOFF=c – Inactive minutes until the unit logs off the user, keeping the connection
open (c = 0 to 255)
SWCONTROL=b – uses software (XON/XOFF) flow control (b = ALW), or no flow control
(b = INH)
097-72060-01 Revision J – June, 2007
Chapter 3 Installing the TimeSource 3600
Powering Up the TimeSource 3600
Procedure
TimeSource 3600 User's Guide
99