Aid
Parameter
TS3600,
TIME=x
SPAN
A & B
SEV1=x
(See Note: 2)
SEV2=x
(See Note: 2)
TS3600,
SAFF1=x
SPAN
(See Note: 2)
A & B,
(cont'd)
SAFF2=x
(See Note: 2)
Note:
1
All commands on DCDUSERPORT TID which equal SID of the DCD are forwarded to the DCD. Similarly,
the responses from the DCD are sent to the provisioned DCDUSERPORT.
2
When setting alarm integration time (SEVERITY or SERAFF), the type of alarm (HOLDOVER, GPS, LOS,
AIS, or ERROR) has to be specified. For example, ED-EQPT::TS3600:CTAG:::ALARM=HOLDOVER,
TIME=72-00, SEVERITY1=EV,SERAFF1=NSA, SEVERITY2=MJ, SERAFF2=SA; will generate a holdover
event as soon as the condition is detected with an NSA flag. Once this condition has existed for 72 hours,
TS3600 will generate a major alarm with an SA flag. These parameters can then be verified using the
RTRV-EQPT command.
097-72060-01 Revision J – June, 2007
Value
x = HH-MM
Hour (00-999) and minute (00-59) time to
escalate alarm
x = 0
No alarm escalation
x = CR
Severity of initial alarm prior to escalation
x = MJ
x = MN
x = EV
x = NA
x = CR
Severity of escalated alarm
x = MJ
x = MN
x = EV
x = NA
x = SA
Service affecting state of initial alarm prior to
escalation
x = NSA
x = SA
Service affecting state of escalated alarm
x = NSA
Chapter 4 TL1 Reference
Commands
Description
TimeSource 3600 User's Guide 165
Need help?
Do you have a question about the TimeSource 3600 and is the answer not in the manual?