Symmetricom TimeSource 3600 User Manual page 164

Gps primary reference source
Hide thumbs Also See for TimeSource 3600:
Table of Contents

Advertisement

Chapter 4 TL1 Reference
Commands
Aid
Parameter
OPT-a
MONITOR=b
(990-720
60-04
systems
only)
ALMOUT=b
OPT-a
FRAMING=b
(990-720
60-06
systems
only)
ALMOUT=b
SPAN
ALARM=x
A & B
164 TimeSource 3600 User's Guide
Value
b = ALW
TimeSource 3600 uses monitoring
information to generate an alarm
b = INH
TimeSource 3600 does not use monitoring
information to generate an alarm
b = AIS
When the ESCIU detects LOS on an input
span, an all-ones signal (AIS), without the E1
alignment sequence, is output to the
downstream network element
b = PASSTHRU
When the ESCIU detects LOS on an input
span, the LOS alarm signal, with the E1
alignment sequence, is passed through to
the downstream network element
b = CAS
Output framing is CAS
b = CAS4
Output framing is CAS4
b = CCS,
Output framing is CCS
b = CCS4
Output framing is CCS4
b = D4
Output framing is D4
b = ESF
Output framing is ESF
b = NONE
Output framing is NONE (analog)
b = AIS
Output during holdover alarm is AIS
b = SQUELCH
No output during holdover alarm
b = SSM
Outputs are at 'STU' quality level for ESF
framing and at 'SSUT' quality level for CAS4
and CCS4 framing during holdover alarm
(SSM requires output framing of CAS4,
CCS4, or ESF)
x = LOS
LOS alarm
x = AIS
AIS alarm
x = ERROR
ERROR alarm
Description