Chapter 4 TL1 Reference
Commands
Aid
Parameter
GPS
ANTCBLDLY=a
ANTELEVMASK=a
ANTMODE=a
MANLAT=a-b-c-d
MANLONG=
a-b-c-d
MANELEV=a
SPAN-a
ENSEMBLER=b
MONITOR=b
SSM=b
SIGNAL=b
162 TimeSource 3600 User's Guide
Value
a = 0 to 305
Antenna cable length (meters)
a = 0 to 45
Antenna elevation mask angle (degrees)
a = AUTO
Automatic survey-in mode
a = MANUAL
Manual survey-in mode (do not use for roof
antenna)
a = N
North latitude
a = S
South latitude
b = 0 to 179
Degrees of latitude
c = 0 to 59
Minutes of latitude
d = 0 to 999
Decimal minutes of latitude
a = E
East longitude
a = W
West longitude
b = 0 to 179
Degrees of longitude
c = 0 to 59
Minutes of longitude
d = 0 to 999
Decimal minutes of longitude
a = 0 to 8000
Antenna elevation (meters)
b = ALW
E1 span is ensembled
b = INH
E1 span is not ensembled
b = ALW
E1 span is monitored
b = INH
E1 span is not monitored
b = ALW
SSM message is used to qualify input
b = INH
SSM message is not used to qualify input
b = ANALOG
Span input signal is 2.048 MHz
b = DIGITAL
Span input signal is 2.048 Mb/s
Description
097-72060-01 Revision J – June, 2007