3.5.5

Time Profile

The procedure of configuring a time profile and applying it to ACL is described.
3.5.5.1
Time Profile Configuration
Configuration using CLI
1) Go to configure of CLI fqm mode.
APC# configure terminal
APC/configure# fqm-mode
2) Configure a time profile. The 'no' parameter is used to delete a time profile.
time-profile [PROFILE_NAME]
day-start (any|YY[-MM[-DD[THH[:MM[:SS]]]]])
day-stop (any|YY[-MM[-DD[THH[:MM[:SS]]]]])
time-start (any|HH:MM[:SS])
time-stop (any|HH:[MM:SS])
monthdays (any|[0-31])
weekdays (any|VARIABLE))
no time-profile [PROFILE_NAME]
Parameter
PROFILE_NAME
3) To check the configured time profile, use the 'show running-config network' command.
Configuration using Web UI
In the menu bar of <WEC Main window>, select <Configuration> and then select the
<Security>  <Access Control Lists>  <Time Profile> menu in the sub-menus.
The configured time profile list is displayed on the window. When you click the <Add> or
<Delete> button, you can add or delete a time profile.
Samsung Electronics America
Figure 42. Time Profile Configuration Window (1)
Description
Name of a time profile to configure
Version 5.2