Mitsubishi Q01CPU User Manual page 674

Melsec-q series, qcpu
Hide thumbs Also See for Q01CPU:
Table of Contents

Advertisement

12
TROUBLESHOOTING
Special
ACPU
Special
Register
Special
Register for
after
Register
Modification
Conversion
D9204
SD1204
D9205
SD1205
D9206
SD1206
D9210
SD1210
D9211
SD1211
D9212
SD1212
D9213
SD1213
D9214
SD1214
D9215
SD1215
D9216
SD1216
D9217
SD1217
D9218
SD1218
D9219
SD1219
12
- 350
12.8 Special Register List
Table12.55 Special register
Name
Meaning
0 : Forward loop,
during data link
1 : Reverse loop,
during data link
2 : Loopback
implemented in
forward/reverse
directions
Link status
3 : Loopback
implemented only
in forward
direction
4 : Loopback
implemented only
in reverse
direction
5 : Data link disabled
Station
Station that
implementing
implemented forward
loopback
loopback
Station
Station that
implementing
implemented reverse
loopback
loopback
Number of
Stored as cumulative
retries
value
Number of
Stored as cumulative
times loop
value
selected
Local station
Stores conditions for
operation status
up to numbers 1 to 16
Stores conditions for
Local station
up to numbers 17 to
operation status
32
Stores conditions for
Local station
up to numbers 33 to
operation status
48
Stores conditions for
Local station
up to numbers 49 to
operation status
64
Local station
Stores conditions for
error detect
up to numbers 1 to 16
status
Local station
Stores conditions for
error detect
up to numbers 17 to
status
32
Local station
Stores conditions for
error detect
up to numbers 33 to
status
48
Local station
Stores conditions for
error detect
up to numbers 49 to
status
64
Details
• Loopback in forward loop only
Master
Station
Station
station
No.1
No.2
Forward loopback
• Loopback in reverse loop only
Master
Station
station
Station
No.1
No.2
Reverse loopback
Stores the local or remote I/O station number at which loopback is
being executed.
Master
station
Station
Station
No.1
No.2
Forward loopback
Reverse loopback
In the above example, 1 is stored into D9205 and 3 into D9206.
If data link returns to normal status (data link in forward loop), values
in D9205 and D9206 remain 1 and 3. To return them to "0", therefore,
use a sequence program or perform reset operation.
Stores the number of retry times due to transmission error.
Count stops at maximum of "FFFF
" .
H
To return the value to "0", perform reset operation.
Stores the number of times the loop line has been switched to reverse
loop or loopback.
Count stops at maximum of "FFFF
".
H
To return the value to "0", perform reset operation.
Stores the local station numbers which are in STOP or PAUSE mode.
Bit
Device
number
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SD1212
L16 L15 L14 L13 L12 L11
L10 L9 L8 L7 L6 L5 L4 L3 L2 L1
SD1213
L32 L31 L30 L29 L28 L27
L26
L25
SD1214
L48 L47 L46 L45 L44 L43
L42
L41
SD1215
L64 L63 L62 L61 L60 L59
L58
L57
When a local station is switched to STOP or PAUSE mode, the bit
corresponding to the station number in the register becomes "1".
Example: When station 7 switches to STOP mode, b6 in SD1212
becomes "1" , and when SD1212 is monitored, its value is
"64 (40
)".
H
Stores the local station numbers which are in error.
Bit
Device
number
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SD1216
L16 L15 L14 L13 L12 L11
L10 L9 L8 L7 L6 L5 L4 L3 L2 L1
SD1217
L32 L31 L30 L29 L28 L27
L26
L25
SD1218
L48 L47 L46 L45 L44 L43
L42
L41
SD1219
L64 L63 L62 L61 L60 L59
L58
L57
If a local station detects an error, the bit corresponding to the station
number becomes "1".
Example: When station 6 and 12 detect an error, b5 and 11 in
SD1216 become "1", and when SD1216 is monitored, its
value is "2080 (820
)".
H
Corresponding
Station
Station n
No.3
Station
Station n
No.3
Station
Station n
No.3
L24
L23
L22
L21
L20
L19
L18
L17
L40
L39
L38
L37
L36
L35
L34
L33
L56
L55
L54
L53
L52
L51
L50
L49
L24
L23
L22
L21
L20
L19
L18
L17
L40
L39
L38
L37
L36
L35
L34
L33
L56
L55
L54
L53
L52
L51
L50
L49
CPU
QnA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents