• Just when the water reaches 90°C (194°F), the
thermostat valve should have lifted by at least
8.0 mm (0.3 in).
Thermostat valve
lift
Over 8.0 mm at 90°C
(0.3 in at 194° F)
• A thermostat failing to satisfy either of the two
requirements
(start-to-open
temperature and
valve lift) must be replaced.
Tighten the thermostat cover bolts to the
specification.
Tightening torque
WATER PUMP
Tightening torque
Item
N·m
kg-m
®
7- 11
0.7- 1.1
@
12- 17
1.2- 1.7
©
7-9
0.7-0.9
10-15N-m
(1.0
~
1.5 kg-m)
(7 .0 - 11 :0 lb-ft)
lb-ft
5.0-8.0
8.5- 12.5
5.0-6.5
Valve lift
COOLING SYSTEM 5-8
@
®
CD
Circlip
®
Water pump driven sprocket
@Chain
@
Water pump chain tensioner
@Bearing
®
0-ring
(j)
Mechanical seal
@Impeller