Dio Setup (Pwc Status) - Cardinal 225 Installation And Technical Manual

Table of Contents

Advertisement

DIO SETUP (PWC Status)

IMPORTANT! The DIO SETUP (PWC Status) cannot be selected if Mode of
Operation = 0, Normal Indicator is enabled.
With the SETUP MENU #1 displayed, press NEXT (Navigation Keys  Down Arrow) to
proceed to SETUP MENU #2.
1. SERIAL
2. DIO
3. PRINT TABS
4. SETUP SCALE 1
5. CALIBRATE 1
Enter Selection: 0
2. DIO (TOGGLE PWC STATUS)
With the SETUP MENU #2 displayed, press the 2 key and then the ENTER key to proceed
to the DIO SETUP MENU.
PWC1-OFF PWC6-OFF
PWC2-OFF PWC7-OFF
PWC3-OFF PWC8-OFF
PWC4-OFF PWC9-OFF
PWC5-OFF PWC10-OFF PWC15-OFF
Enter PWC # to Toggle: 0
With the DIO SETUP MENU displayed, the current "state before cutoff" status of the 16
Preset Weight Comparators (PWC) will be shown. If the status displayed is acceptable,
press EXIT (Navigation Keys  UP Arrow) to exit and return to the SETUP MENU #2.
Otherwise, press the PWC number, 17 or 18 to toggle the status (turn ON, relay closed
or OFF, relay open) and then press the ENTER key to save the new setting.
IMPORTANT! When power to the indicator is lost, the output goes to the OFF state.
60
CALIBRATION AND SETUP, CONT.
SETUP MENU #2
DIO SETUP MENU
8200-M698-O1 Rev B  225 Installation and Technical
`
NEXT
^
PREV
PWC11-OFF PWC16-OFF
PWC12-OFF 17. ALL OFF
PWC13-OFF 18. ALL ON
PWC14-OFF
^
EXIT