Setup Review - Cardinal Priefert 190P Quick Setup Manual

Digital weight indicator
Table of Contents

Advertisement

SETUP REVIEW

Accessing Setup Review
Page 10
The 190 indicator allows several operational parameters to be reviewed
and changed without breaking the calibration seal.
With the indicator ON, press Fn/ key and then the ZERO key.
1.
The display will change to show td= (the prompt for selection of a
2.
12 or 24 hour clock).
Press the TARE  key to show the current setting. If the setting
3.
displayed is acceptable, press the TARE  key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE  key to save it and advance to the next prompt.
To exit Setup Review, press the TARE  key to step through the
4.
remaining prompts OR at any time, cycle the power (press the
ON/OFF key twice).
Td=
Time and Date (Select 12 or 24 hour clock)
Digital Input (Disable or Select key function)
d in=
Digital Output (Disable or Select Preset/Checkweigher
d out=
function)
Sleep Mode (Disable or Select number of minutes
SLEEP=
before entering sleep mode)
Auto Shutoff (Disable or Select number of minutes
A off=
before automatic shutoff)
Key Touch Sensitivity (Select number of milliseconds
toUCH=
key must be touched before key press is acted upon)
Sio?
Serial Input/Output Configuration
(Select YES or NO)
baUd=
Select Serial Port Baud Rate
prty=
Select Serial Port Parity
Enable or Disable Continuous Output to the Serial Port
Cont1=
type= If Cont1=YES
(Select Continuous Output Format, SMA or Cardinal
Scoreboard)

Advertisement

Table of Contents
loading

Table of Contents