Calibration "C" Numbers - Cardinal 225 Installation And Technical Manual

Table of Contents

Advertisement

Calibration "C" Numbers

The calibration "C" numbers (C1, C2, C3 and C4) represent the present calibration
settings. Each number may be up to three (3) digits in length. These values are
established when the scale is calibrated. To return the indicator to its present calibration
settings (without using test weights) enter the calibration "C" numbers.
6. C1=XXX
7. C2=XXX
8. C3=XXX
9. C4=XXX
With the SCALE 1 CALIBRATION MENU displayed the current setting for the C1=,
C2=, C3= and C4= parameters will be shown. Note that XXX is the current value for
the calibration "C" number. If the settings displayed match the numbers recorded
previously, proceed to the next setup parameter.
Otherwise, press the 6, 7, 8 or 9 key, (for the "C" number to be changed), the ENTER
key and then using the numeric keys, enter the value for the "C" number and then press
the ENTER key to save the new setting and return to the SCALE 1 CALIBRATION
MENU. Allowable values are 1 through 255.
If any components have been changed that affect calibration and/or the scale is
used in a commercial application and must be "Legal for Trade", calibration
parameters or the "C" numbers cannot be use to re-calibrate.
Scale 1 Calibration Completed
The SCALE 1 calibration has been completed, press EXIT (Navigation Keys  UP Arrow) to
return to SETUP MENU #2.
1. SERIAL
2. DIO
3. PRINT TABS
4. SETUP SCALE 1
5. CALIBRATE 1
Enter Selection: 0
With the SETUP MENU #2 displayed,
 Press PREV (Navigation Keys  UP Arrow) to return to SETUP MENU #1.
 Press NEXT (Navigation Keys  Down Arrow) to proceed to the SETUP MENU #3.
CALIBRATION AND SETUP, CONT.
CALIBRATION "C" NUMBERS
SETUP MENU #2
8200-M698-O1 Rev B  225 Installation and Technical
`
NEXT
^
PREV
85

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents