ELECTRONIC TALLEY ROLL (ETR) FILE

The 225 is equipped with an Electronic Talley Roll (ETR) feature that stores the weight and a
consecutive transaction number each time the indicator receives a Talley command from the
computing peripheral. The data is maintained in non-volatile memory and is available for use
by a weights and measures inspector.
When enabled, each time the indicator receives an ETR request (SMA XT command), the
gross weight and an internal consecutive transaction number (that cannot be modified) will be
stored in memory. The 225 has sufficient memory to create an ETR file that will store up to
7000 transactions. The ETR file is structured such that when its capacity is reached, the
newest transaction will replace the oldest. The ETR file can only be displayed and cannot be
manually cleared or printed.
Enabling the Electronic Talley Roll (ETR)
To enable the Electronic Talley Roll (ETR) feature, the following parameters must be set:
In SETUP MENU #1
 USA=NO
 MODE OF OP= (0, 2, 3, 4 or 5)
In SETUP MENU #2, 1. SERIAL, 2.COMX (Note that X is the COM port the
indicator receives a Talley command from the computing peripheral)
 5. CONT=NO
 6. TYPE=9 TALLEY
Viewing the Electronic Talley Roll (ETR) File
1. With the indicator in normal operations mode, press the SHIFT and then  /ESC key.
2. The display will change to show the FUNCTION= prompt.
3. Press the ZERO key.
4. The display will show FIND ETR=0.
5. Using the numeric keys, enter the transaction number to find and then press the ENTER
key.
6. The indicator will display ETR=XXXXXXYY for 3 seconds. Note that XXXXXX is the
weight and YY is the units of measurement.
7. After displaying the record, the display will return to normal operation.