Continuous Output Formats - Cardinal 225 Installation And Technical Manual

Table of Contents

Advertisement

SMA – (Type=0)
<lf><s><r><n><m><f><xxxxxx.xxx><uuu><cr>
Where:
lf =
s =
r =
n =
m =
f =
xxxxxx.xxx = Weight
uuu =
cr =
SB-400 – (Type=1)
<s><xxxxxx><d><uu><m><cc><cr>
Where:
s =
xxxxxx.xxx = Weight
d =
uu =
m =
cc =
cr =

CONTINUOUS OUTPUT FORMATS

Line Feed
Flags
Range
Mode
Motion
Custom
Units
Carriage Return
Sign
Decimal point
Units
Mode
Weight Status
Carriage Return
8200-M698-O1 Rev B  225 Installation and Technical
Z= center of Zero, O = Over cap, E = zero Error,
e = weight not currently being displayed
1, 2, 3, ...
G = Gross, T = Tare, N = Net
M = Motion, " "(blank) = no motion
Custom flag
Six digits with decimal point
ton, lb, oz, t, kg, g
(hex 0D)
"-" = negative, " " (blank) = positive
Six digits
Added to string if enabled in setup
tn, lb, oz, t, kg, g
G = Gross, N = Net
OC = over capacity
CZ = center of zero
MO = motion
ee = weight not currently being displayed
(hex 0D)