Page 1
CHECK WEIGHER For The 225 Weight Indicator Installation, Setup and Operation Manual 8200-M564-O1 Rev A PO BOX 151 WEBB CITY, MO 64870 Printed in USA 08/09 PH (417) 673-4631 FAX (417) 673-5001 www.cardinalscale.com Technical Support: Ph: 866-254-8261 techsupport@cardet.com 8200-M564-O1 225 Check Weigher...
Note that these outputs (defined on the next page) are at logic level and cannot drive external devices directly. Solid-state relays can be used to accept the logic level output from the 225 and in turn, drive the external device. Output Cable Installation 1.
Page 4
Over Relay Box Assembly RB4-ACOUT or RB8-ACOUT Figure No. 1 Relay Box Cable Wire Number to Relay Number Table The relay box cable wire numbers correspond to the 225 indicator P15 terminal connections. CABLE WIRE RELAY NUMBER CABLE WIRE RELAY NUMBER...
OPTICALLY ISOLATED REMOTE INPUTS The Model 225 has seven (7) programmable inputs that may be used to remotely (up to 100 feet) initiate various functions within the indicator. These inputs are accessed via a terminal block (P17) on the back of the Main PC board. The 7 inputs are defined on the following page.
Page 6
Relay Box Assembly RB4-ACINV or RB8-ACINV START Figure No. 2 DUMP Relay Box Cable Wire Number to Relay Number Table The relay box cable wire numbers correspond to the 225 indicator P17 terminal connections. CABLE WIRE RELAY NUMBER CABLE WIRE RELAY NUMBER...
CAUTION! This board contains static sensitive components. Improper handling can result in damage to or destruction of the components or board. Such actual and/or consequential damage IS NOT covered under warranty. Figure No. 3 8200-M564-O1 225 Check Weigher Page 5...
Page 8
J6 (REMOTE IN) – REMOTE IN JUMPER When installed, this jumper allows the 225 indicator to supply (source) 5 VDC to a remote input circuit. Connecting P17 pins 1 through 9 to P17 pin 10 (GND) through a switch will cause the selected action.
2. Ensure any unused gland connectors are plugged and replace the rear panel. 3. Secure the rear panel with the 14 acorn nuts removed earlier. 4. Follow a diagonal pattern when tightening the acorn nuts. 8200-M564-O1 225 Check Weigher Page 7...
Page 10
When OUTPUTS=3 is selected, the check weigher will compare the displayed weight with either high and low preset values. When OUTPUTS=5 is selected, the check weigher will compare the displayed weight with high, high-accept, low-accept and low preset values. 8200-M564-O1 225 Check Weigher Page 8...
Page 11
PWC5 OVER The relay state is based on using Cardinal Scale relays (p/n 6850-1013). If using relays other than those supplied by Cardinal Scale, refer to the relay manufacturers specifications. NOTE! When power to the indicator is lost, the output returns to a Low State condition.
ENTER key to save it. Note that the over value must be greater than the under value. 6. After the over preset value is entered, the 225 will return to normal operation. 8200-M564-O1 225 Check Weigher...
Page 13
ENTER key to save it. Note that the over value must be greater than the high accept value. 7. After the over preset value is entered, the 225 will return to normal operation. NOTE! Remember that the check weigher function operates on the absolute value of the weight ignoring the polarity.
Need help?
Do you have a question about the 225 and is the answer not in the manual?