Test Mode And Diagnostic Display - Cardinal 225 Installation And Technical Manual

Table of Contents

Advertisement

TEST MODE AND DIAGNOSTIC DISPLAY

Test Mode
The Test mode is used to display the software revision number, the calibration "C" numbers,
and conduct a test of all display elements. The test consists of 6 cycles:
1. With the indicator in normal operations mode, press the SHIFT and then  /ESC key.
2. The display will change to show the FUNCTION= prompt.
3. Press the UNITS key.
4. The display will show the model number and the software revision.
5. Next, a graphics display test will be performed.
6. After the display test, the 225 will display the calibration "C" numbers (C1 to C4) for
approximately 5 seconds.
7. After displaying the "C" numbers, the display will return to normal operation.
Diagnostic Display
The 225 can provide a diagnostic display to help determine how the load cells and weight
measuring circuitry are functioning.
1. With the indicator in normal operations mode, press the SHIFT key and then the
Navigation ENTER key (red square key).
2. The display will change to show the SETUP/REVIEW MENU.
3. Using the numeric keys, enter 225 and then press the ENTER key.
4. The display will change to show the diagnostic display:
SCALE
NUMBER
S1
S2
S3
TESTONLYTESTONLYTESTONLYTESTONLYTESTONLY
NOTE: Labels are for reference only and are not shown on 225 display.
RAW ADC
COUNT
XXXXXXXX
XXXXXXXX
XXXXXXXX
8200-M698-O1 Rev B  225 Installation and Technical
SCALE mV
SCALE
INPUT
WEIGHT
XX.X mV
XXXXXX
XX.X mV
XXXXXX
XX.X mV
XXXXXX
SCALE
UNITS
lb G
lb G
lb G
129