To set up analog trunk on the UCM6510:
Go to web GUI->PBX->Basic/Call Routes->Analog Trunks to add and edit analog trunks.
Go to web GUI->PBX->Ports Config->Analog Hardware to configure analog hardware settings.

ANALOG TRUNKS CONFIGURATION

Go to web GUI->PBX->Basic/Call Routes->Analog Trunks to add and edit analog trunks.
Click on "Create New Analog Trunk" to add a new analog trunk.
Click on
to edit the analog trunk.
Click on
to delete the analog trunk.
The analog trunk options are listed in the table below.
Channels
Trunk Name
Advanced Options
Enable Polarity Reversal
Polarity on Answer Delay
Current Disconnect Threshold
(ms)
Firmware Version 1.0.0.5

ANALOG TRUNKS

Table 22: Analog Trunk Configuration Parameters

Select the channel for the analog trunk.
Specify a unique label to identify the trunk when listed in outbound rules,
incoming rules and etc.
If enabled, a polarity reversal will be marked as received when an
outgoing call is answered by the remote party. For some countries, a
polarity reversal is used for signaling the disconnection of a phone line
and the call will be considered as "hangup" on a polarity reversal. The
default setting is "No".
When FXO port answers the call, FXS may send a Polarity Reversal. If
this interval is shorter than the value of "Polarity on Answer Delay", the
Polarity Reversal will be ignored. Otherwise, the FXO will onhook to
disconnect the call. The default setting is 600ms.
This is the periodic time (in ms) that the UCM6510 will use to check on a
voltage drop in the line. The default setting is 200. The valid range is 50
to 3000.