Manipulating Files
Related Auxiliary Bits/Words
Name
File Memory Operation Flag
EM File Memory Starting Bank
Network Communications
Instruction Enabled Flags (CS1-
H, CJ1-H, CJ1M, or CS1D CPU
Units only) (See note.)
Network Communications Com-
pletion Code (CS1-H, CJ1-H,
CJ1M, or CS1D CPU Units only)
(See note.)
Network Communications Error
Flags (CS1-H, CJ1-H, CJ1M, or
CS1D CPU Units only) (See
note.)
Simple Backup Write Capacity
(CS1-H, CJ1-H, CJ1M, or CS1D
CPU Units only)
Backing Up Board and Unit Data
Introduction
Outline
242
Address
A34313
ON when any of the following are being performed. OFF when execution
has been completed.
• Memory Card detection
• CMND instruction executed for local CPU Unit
• FREAD/FWRIT instructions
• Program replacement via special control bits
• Simple backup operation
Wiring data to or verifying the contents of the Memory Card is not possi-
ble while this flag is ON.
A344
When the CPU Unit starts reading from the Memory Card, it references
this value. If the maximum EM bank number of the BACKUPE@.IOM files
(maximum consecutive bank number counting from 0) matches the maxi-
mum bank number of the CPU Unit, the EM area will be formatted based
on the value in this word. If the maximum EM bank numbers do not
match, the EM Area will revert to its unformatted condition.
A20200 to
• Turns OFF when writing or comparing Memory Card data begins.
A20207
• Turn ON when writing or comparing Memory Card data has been com-
pleted.
Unit and Board data cannot be written or compared if all of the Network
Communications Instruction Enabled Flags are OFF when Memory Card
write or compare operations are started and an error will occur if this is
attempted.
A203 to
Provide the results of communications with the Unit or Board when Mem-
A210
ory Card write or compare operations are performed.
A21900 to
• Turns ON is an error occurs in communications with the Unit or Board
A21907
when Memory Card write or compare operations are performed.
• Remains OFF (or turns OFF) is no error occurs in communications with
the Unit or Board when Memory Card write or compare operations are
performed.
A397
Provides the data capacity in Kbytes that would be required on the Mem-
ory Card when writing fails for a simple backup operation, indicating that
a write error occurred because of insufficient capacity.
0001 to FFFF Hex: Write error (Indicates required Memory Card capacity
between 1 and 65,535 Kbytes.) (Cleared to 0000 Hex when successful
write is performed.)
0000 Hex: Write completed normally.
Note These flags are related for the CS1-H, CJ1-H, CJ1M, or CS1D CPU Units
because the CPU Unit will automatically using an available communications
port when writing or comparing data for a Memory Card.
This function is supported only by CS1-H, CJ1-H, CJ1M, or CS1D CPU Units.
The following data is backed up from the CPU Unit by the CS1 and CJ1 CPU
Units for the simple backup operation: User program, parameter area, entire
I/O memory. In addition to the above data, the following data is also backed up
for the CS1-H, CJ1-H, CJ1M, or CS1D CPU Units: Data from specific Units
and Boards mounted to the PLC.
When the simple backup operation is used for a CS1-H, CJ1-H, CJ1M, or
CS1D CPU Unit, a Unit/Board backup file containing data from specific Units
Description
Section 5-2