Yes (Rs-232C X 1); C200Hx/Hg; Cvm1/Cv; Series - Omron CS1G/H-CPUxx-EV1 Programming Manual

Sysmac cs series; sysmac cj series
Hide thumbs Also See for CS1G/H-CPUxx-EV1:
Table of Contents

Advertisement

PLC Comparison Charts
Item
Table Data
SET STACK
Processing
Instructions
PUSH ONTO
STACK:
FIRST IN FIRST
OUT
LAST IN FIRST
OUT
FIND MAXIMUM/
FIND MINIMUM
DATA SEARCH
FRAME CHECK-
SUM
SUM
SWAP BYTES
DIMENSION
RECORD TABLE:
SET RECORD
LOCATION
GET RECORD
LOCATION
Mne-
CJ Series
monic
SSET
Yes (Four words
Yes (Four words
of stack control
of stack control
information.
information.
Number of
Number of
words specified
words specified
in binary: 5 to
in binary: 5 to
65535)
65535)
PUSH
Yes
Yes
FIFO
Yes
Yes
LIFO
Yes
Yes
MAX,
Yes (Two words
Yes (Two words
MIN
in control data
in control data
field. Table
field. Table
length specified
length specified
in binary: 1 to
in binary: 1 to
FFFF)
FFFF)
SRCH
Yes (Table
Yes (Table
length specified
length specified
in binary: 1 to
in binary: 1 to
FFFF. PLC
FFFF. PLC
memory address
memory address
output to IR0.
output to IR0.
Number of
Number of
matches can be
matches can be
output to DR0)
output to DR0)
FCS
Yes
Yes
SUM
Yes (Same as
Yes (Same as

C200HX/HG/

C200HX/HG/
HE: Sum possi-
HE: Sum possi-
ble for bytes as
ble for bytes as
well as words.)
well as words.)
SWAP
Yes (Can be
Yes (Can be
used for data
used for data
communications
communications
and other appli-
and other appli-
cations.)
cations.)
DIM
Yes
Yes
SETR
Yes
Yes
GETR
Yes
Yes
CS Series
C200HX/HG/HE
No
No
No
No
Yes (One word
in control data
field. Table
length specified
in BCD: 1 to
999)
Yes (Table
length specified
in BCD: 1 to
6556. PLC
memory address
output to C+1.
Number of
matches cannot
be output to
DR0)
Yes
Yes (Sum possi-
ble for bytes as
well as words.)
No
No
No
No
Appendix A

CVM1/CV

CQM1H

Series

Yes (Four words
No
of stack control
information.
Number of
words specified
in BCD: 3 to
9999)
Yes
No
Yes
No
Yes
No
Yes (One word
Yes (One word
in control data
in control data
field. Table
field. Table
length specified
length specified
in BCD: 1 to
in BCD: 1 to
999)
999)
Yes (Table
Yes (Table
length specified
length specified
in BCD: 1 to
in BCD: 1 to
9999. PLC
6556. PLC
memory address
memory address
output to IR0.
output to C+1.
Number of
Number of
matches cannot
matches cannot
be output to
be output to
DR0)
DR0)
No
Yes
Yes (Sum possi-
Yes (Sum possi-
ble for words
ble for bytes as
only.)
well as words.)
No
No
No
No
No
No
No
No
375

Advertisement

Table of Contents
loading

Table of Contents