Timer and Counter Instructions

3-4
Timer and Counter Instructions
Instruction
Symbol/Operand
Mnemonic
Code
TIMER
TIM
TIM
(BCD)
TIMX
(Binary)
N: Timer number
(CS1-H, CJ1-H,
S: Set value
CJ1M, or CS1D
only)
TIMX(550)
N: Timer number
S: Set value
HIGH-SPEED
TIMH(015)
TIMER
TIMH
015
(BCD)
N: Timer number
TIMHX
S: Set value
551
(Binary)
(CS1-H, CJ1-H,
TIMHX(551)
CJ1M, or CS1D
only)
N: Timer number
S: Set value
ONE-MS TIMER
TMHH(540)
TMHH
540
(BCD)
TMHHX
N: Timer number
552
S: Set value
(BCD)
(CS1-H, CJ1-H,
CJ1M, or CS1D
TMHHX(552)
only)
N: Timer number
S: Set value
TIM/TIMX(550) operates a decrementing timer with units of 0.1-s.
The setting range for the set value (SV) is 0 to 999.9 s for BCD
N
and 0 to 6,553.5 s for binary (decimal or hexadecimal).
S
Timer input
Timer PV
Completion
N
Flag
S
Timer input
Timer PV
Completion
Flag
TIMH(015)/TIMHX(551) operates a decrementing timer with units
of 10-ms. The setting range for the set value (SV) is 0 to 99.99 s
N
for BCD and 0 to 655.35 s for binary (decimal or hexadecimal).
S
Timer input
Timer PV
Completion
Flag
N
S
Timer input
Timer PV
Completion
Flag
TMHH(540)/TMHHX(552) operates a decrementing timer with units of
1-ms. The setting range for the set value (SV) is 0 to 9.999 s for BCD
and 0 to 65.535 s for binary (decimal or hexadecimal).
N
The timing charts for TMHH(540) and TMHHX(552) are the same as
those given above for TIMH(015).
S
N
S
Function
SV
SV
SV
SV
Section 3-4
Location
Execution condition
Output
Required
Output
Required
Output
Required
81