Preparation
This sewing machine stands up for oneself in the state that the front cover assy and rear cover assy are removed.
There are feasible adjustments without covers, but recommend that adjust after removing the front cover assy and rear
cover assy basically.
1. Turn off the power switch, and then disconnect the plug of the foot controller from the electrical outlet.
2. Disconnect the 3-pin connector of the foot controller from the 3P socket of the machine.
3. Remove the accessory table.
4. Remove the screw (taptite, cup P M4X20) from the rear cover side, and then open the bottom side of face plate
assy to remove the face plate assy from the rear cover assy.
5. Remove the pattern selecting dial from the shaft of pattern selecting unit assy.
6. Remove the screw (screw, pan (S/P washer) M3X6) from the front cover side. And remove the three screws
(taptite, cup P M4X20) and screw (taptite, bind P M3X16) from the rear cover side.
7. Release the five hooks of front cover assy from the five hook trays of rear cover assy, and then open the
bottom side of front cover assy to remove the front cover assy from the rear cover assy.
Taptite, cup P
M4X20
Taptite, bind P
M3X16
Taptite, cup P
M4X20
Rear cover
assy
<To next page>

Removal of covers

Taptite, bind P M3X16
Taptite, cup P M4X20
(Face plate assy)
Taptite, cup P M4X20
Hook trays
Hooks
Face plate assy
4 - 2
Taptite, Cup P M4X20
Screw, Pan (S/P washer) M3X6
Taptite, Bind P M3X16
Hook tray
Shaft of pattern
selecting unit assy
Front cover assy
Hook trays
Screw, pan (S/P washer) M3X6
Hooks
Pattern
selecting dial