Basic of Disassembly
Bobbin winder, Upper shaft, Needle-presser module
1
Removal of Bobbin winder assy
1. Remove the two screws (taptite, bind S M4X10) to remove the bobbin winder assy from the arm bed.
→
Refer to 3 - 24 Disassembly of Bobbin winder assy.
Taptite, Bind S M4X10
Taptite, bind S M4X10
Bobbin winder assy