Keithley 2461 Reference Manual page 1096

1kw pulse mode interactive sourcemeter instrument
Table of Contents

Advertisement

Appendix D: Convert Model 2400 to Model 2461 code
Model 2400 command
Model 2461 command
Notes
Model 2400 command
Model 2461 command
Notes
Model 2400 command
Model 2461 command
Notes
Model 2400 command
Model 2461 command
Notes
Model 2400 command
Model 2461 command
Notes
Model 2400 command
Model 2461 command
Notes
Model 2400 command
Model 2461 command
Notes
Model 2400 command
Model 2461 command
Notes
Model 2400 command
Model 2461 command
Notes
Model 2400 command
Model 2461 command
Notes
D-24
Model 2461 Interactive SourceMeter® Instrument Reference Manual
:STATus:MEASurement[:EVENt]?
Not available
Use the questionable register to emulate this register; see the
subsystem
(on page 6-133) for information.
:STATus:OPERation:CONDition?
:STATus:OPERation:CONDition?
In the Model 2461, you need to map events into the register (there are no set
bits). See
Status model
(on page C-1) for information.
:STATus:OPERation:ENABle
:STATus:OPERation:ENABle?
:STATus:OPERation:ENABle
:STATus:OPERation:ENABle?
In the Model 2461, you need to map events into the register (there are no set
bits). See
Status model
(on page C-1) for information.
:STATus:OPERation[:EVENt]?
:STATus:OPERation[:EVENt]?
In the Model 2461, you need to map events into the register (there are no set
bits). See
Status model
(on page C-1) for information.
:STATus:PRESet
:STATus:PRESet
(on page 6-136)
:STATus:QUEStionable:CONDition?
:STATus:QUEStionable:CONDition?
In the Model 2461, you need to map events into the register (there are no set
bits). See
Status model
(on page C-1) for information.
:STATus:QUEStionable:ENABle
:STATus:QUEStionable:ENABle?
:STATus:QUEStionable:ENABle
:STATus:QUEStionable:ENABle?
In the Model 2461, you need to map events into the register (there are no set
bits). See
Status model
(on page C-1) for information.
:STATus:QUEStionable[:EVENt]?
:STATus:QUEStionable[:EVENt]?
In the Model 2461, you need to map events into the register (there are no set
bits). See
Status model
(on page C-1) for information.
:STATus:QUEue:CLEar
Not available
Use the event log; see
Using the event log
:STATus:QUEue:DISable
:STATus:QUEue:DISable?
Not available
Use the event log; see
Using the event log
(on page 6-133)
(on page 6-134)
(on page 6-134)
(on page 6-136)
(on page 6-137)
(on page 6-138)
(on page 2-142).
(on page 2-142).
2461-901-01 A/November 2015