GE G60 Instruction Manual page 353

Generator management relay
Hide thumbs Also See for G60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 28 of 40)
ADDR
REGISTER NAME
B314
Digital Counter 1 Set To Preset
B315
Reserved (11 items)
B320
...Repeated for Digital Counter 2
B340
...Repeated for Digital Counter 3
B360
...Repeated for Digital Counter 4
B380
...Repeated for Digital Counter 5
B3A0
...Repeated for Digital Counter 6
B3C0
...Repeated for Digital Counter 7
B3E0
...Repeated for Digital Counter 8
Frequency Rate of Change (Read/Write Setting) (4 modules)
B500
Frequency Rate of Change 1 Function
B501
Frequency Rate of Change 1 OC Supervision
B502
Frequency Rate of Change 1 Min
B503
Frequency Rate of Change 1 Max
B504
Frequency Rate of Change 1 Pickup Delay
B505
Frequency Rate of Change 1 Reset Delay
B506
Frequency Rate of Change 1 Block
B507
Frequency Rate of Change 1 Target
B508
Frequency Rate of Change 1 Events
B509
Frequency Rate of Change 1 Source
B50A
Frequency Rate of Change 1 Trend
B50B
Frequency Rate of Change 1 Pickup
B50C
Frequency Rate of Change 1 OV Supervision
B50D
Frequency Rate of Change 1 Reserved (3 items)
B510
...Repeated for Frequency Rate of Change 2
B520
...Repeated for Frequency Rate of Change 3
B530
...Repeated for Frequency Rate of Change 4
IEC 61850 GSSE Configuration (Read/Write Setting)
B680
Default GSSE Update Time
B681
Remote Input/Output Transfer Method
B682
IEC 61850 GOOSE VLAN Transmit Priority
B683
IEC 61850 GOOSE VLAN ID
B684
IEC 61850 GOOSE ETYPE APPID
B685
Reserved (22 items)
IEC 61850 Server Configuration (Read/Write Setting)
B6A0
TCP Port Number for the UCA/MMS Protocol
B6A1
IEC 61850 Logical Device Name
B6A9
Include Non-IEC 61850 Data
B6AA
Reserved (22 items)
IEC 61850 Logical Node Name Prefixes (Read/Write Setting)
B700
IEC 61850 Logical Node PIOCx Name Prefix (40 items)
B778
IEC 61850 Logical Node PTOCx Name Prefix (20 items)
B7B4
IEC 61850 Logical Node PTUVx Name Prefix (8 items)
B7CC
IEC 61850 Logical Node PTOVx Name Prefix (8 items)
B7E4
IEC 61850 Logical Node PDISx Name Prefix (10 items)
B802
IEC 61850 Logical Node RRBFx Name Prefix (26 items)
B850
IEC 61850 Logical Node RPSBx Name Prefix
B853
IEC 61850 Logical Node RRECx Name Prefix (6 items)
B865
IEC 61850 Logical Node MMXUx Name Prefix (6 items)
B877
IEC 61850 Logical Node GGIOx Name Prefix (2 items)
B87D
IEC 61850 Logical Node RFLOx Name Prefix (6 items)
B88F
IEC 61850 Logical Node XCBRx Name Prefix (2 items)
B895
IEC 61850 Logical Node PTRCx Name Prefix (2 items)
GE Multilin
RANGE
0 to 65535
---
0 to 1
0 to 30
20 to 80
20 to 80
0 to 65.535
0 to 65.535
0 to 65535
0 to 2
0 to 1
0 to 5
0 to 2
0.1 to 15
0.1 to 3
0 to 1
1 to 60
0 to 2
0 to 7
0 to 4095
0 to 16383
0 to 1
1 to 65535
---
0 to 1
0 to 1
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
G60 Generator Management Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F300
---
---
F001
---
1
F102
pu
0.001
F001
Hz
0.01
F001
Hz
0.01
F001
s
0.001
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F167
---
1
F224
Hz/s
0.01
F001
pu
0.001
F001
---
1
F001
s
1
F001
---
1
F226
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
---
F203
---
1
F102
---
1
F001
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
DEFAULT
0
0
B
0 (Disabled)
200
4500
6500
0
0
0
0 (Self-reset)
0 (Disabled)
0 (SRC 1)
0 (Increasing)
50
700
0
60
1 (GSSE)
4
0
0
0
102
"IECDevice"
1 (Enabled)
0
(None)
(None)
(None)
(None)
(None)
(None)
(None)
(None)
(None)
(None)
(None)
(None)
(None)
B-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ur series

Table of Contents