GE G60 Instruction Manual page 140

Generator management relay
Hide thumbs Also See for G60:
Table of Contents

Advertisement

5.4 FLEXLOGIC™
Table 5–5: G60 FLEXLOGIC™ OPERANDS (Sheet 6 of 6)
OPERAND TYPE
OPERAND SYNTAX
SELF-
ANY MAJOR ERROR
DIAGNOSTICS
ANY MINOR ERROR
ANY SELF-TEST
BATTERY FAIL
DIRECT DEVICE OFF
DIRECT RING BREAK
DSP ERROR
EEPROM DATA ERROR
EQUIPMENT MISMATCH
FLEXLOGIC ERR TOKEN
IRIG-B FAILURE
LATCHING OUT ERROR
LOW ON MEMORY
NO DSP INTERRUPTS
PRI ETHERNET FAIL
PROGRAM MEMORY
PROTOTYPE FIRMWARE
REMOTE DEVICE OFF
SEC ETHERNET FAIL
SNTP FAILURE
SYSTEM EXCEPTION
UNIT NOT CALIBRATED
UNIT NOT PROGRAMMED
WATCHDOG ERROR
UNAUTHORIZED
UNAUTHORIZED ACCESS
ACCESS ALARM
USER-
PUSHBUTTON x ON
PROGRAMMABLE
PUSHBUTTON x OFF
PUSHBUTTONS
5
Some operands can be re-named by the user. These are the names of the breakers in the breaker control feature, the ID
(identification) of contact inputs, the ID of virtual inputs, and the ID of virtual outputs. If the user changes the default name/
ID of any of these operands, the assigned name will appear in the relay list of operands. The default names are shown in
the FlexLogic™ operands table above.
The characteristics of the logic gates are tabulated below, and the operators available in FlexLogic™ are listed in the Flex-
Logic™ operators table.
Table 5–6: FLEXLOGIC™ GATE CHARACTERISTICS
GATES
NUMBER OF INPUTS
NOT
OR
AND
NOR
NAND
XOR
5-58
OPERAND DESCRIPTION
Any of the major self-test errors generated (major error)
Any of the minor self-test errors generated (minor error)
Any self-test errors generated (generic, any error)
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
See description in Chapter 7: Commands and Targets.
Asserted when a password entry fails while accessing a password-protected
level of the relay.
Pushbutton Number x is in the 'On' position
Pushbutton Number x is in the 'Off' position
OUTPUT IS '1' (= ON) IF...
1
input is '0'
2 to 16
any input is '1'
2 to 16
all inputs are '1'
2 to 16
all inputs are '0'
2 to 16
any input is '0'
2
only one input is '1'
G60 Generator Management Relay
5 SETTINGS
GE Multilin

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ur series

Table of Contents