GE G60 Instruction Manual page 136

Generator management relay
Hide thumbs Also See for G60:
Table of Contents

Advertisement

5.4 FLEXLOGIC™
Table 5–5: G60 FLEXLOGIC™ OPERANDS (Sheet 2 of 6)
OPERAND TYPE
OPERAND SYNTAX
ELEMENT:
FxE 1 PKP
FlexElements™
FxE 1 OP
FxE 1 DPO
FxE 16 PKP
FxE 16 OP
FxE 16 DPO
ELEMENT:
GEN UNBAL STG1 PKP
Generator
GEN UNBAL STG1 DPO
Unbalance
GEN UNBAL STG1 OP
GEN UNBAL STG2 PKP
GEN UNBAL STG2 DPO
GEN UNBAL STG2 OP
GEN UNBAL PKP
GEN UNBAL DPO
GEN UNBAL OP
ELEMENT:
GROUND IOC1 PKP
Ground
GROUND IOC1 OP
Instantaneous
GROUND IOC1 DPO
Overcurrent
GROUND IOC2
ELEMENT:
GROUND TOC1 PKP
Ground Time
GROUND TOC1 OP
Overcurrent
GROUND TOC1 DPO
GROUND TOC2
ELEMENT
LATCH 1 ON
Non-Volatile
LATCH 1 OFF
Latches
5
LATCH 16 ON
LATCH 16 OFF
ELEMENT:
LOSS EXCIT STG1 PKP
Loss of Excitation
LOSS EXCIT STG2 PKP
LOSS EXCIT STG1 DPO
LOSS EXCIT STG2 DPO
LOSS EXCIT STG1 OP
LOSS EXCIT STG2 OP
LOSS EXCIT PKP
LOSS EXCIT DPO
LOSS EXCIT OP
ELEMENT:
NEG SEQ DIR OC1 FWD
Negative Sequence
NEG SEQ DIR OC1 REV
Directional
NEG SEQ DIR OC2 FWD
Overcurrent
NEG SEQ DIR OC2 REV
ELEMENT:
NEG SEQ OV PKP
Negative Sequence
NEG SEQ OV DPO
Overvoltage
NEG SEQ OV OP
ELEMENT:
NEUTRAL IOC1 PKP
Neutral
NEUTRAL IOC1 OP
Instantaneous
NEUTRAL IOC1 DPO
Overcurrent
NEUTRAL IOC2
ELEMENT:
NEUTRAL OV1 PKP
Neutral Overvoltage
NEUTRAL OV1 DPO
NEUTRAL OV1 OP
ELEMENT:
NEUTRAL TOC1 PKP
Neutral Time
NEUTRAL TOC1 OP
Overcurrent
NEUTRAL TOC1 DPO
ELEMENT:
NTRL DIR OC1 FWD
Neutral Directional
NTRL DIR OC1 REV
Overcurrent
NTRL DIR OC2
ELEMENT:
OVERFREQ 1 PKP
Overfrequency
OVERFREQ 1 OP
OVERFREQ 1 DPO
OVERFREQ 2 to 4
5-54
OPERAND DESCRIPTION
FlexElement™ 1 has picked up
FlexElement™ 1 has operated
FlexElement™ 1 has dropped out
FlexElement™ 16 has picked up
FlexElement™ 16 has operated
FlexElement™ 16 has dropped out
The Generator Unbalance Stage 1 element has picked up
The Generator Unbalance Stage 1 element has dropped out
The Generator Unbalance Stage 1 element has operated
The Generator Unbalance Stage 2 element has picked up
The Generator Unbalance Stage 2 element has dropped out
The Generator Unbalance Stage 2 element has operated
The Generator Unbalance element has picked up
The Generator Unbalance element has dropped out
The Generator Unbalance element has operated
Ground Instantaneous Overcurrent 1 has picked up
Ground Instantaneous Overcurrent 1 has operated
Ground Instantaneous Overcurrent 1 has dropped out
Same set of operands as shown for GROUND IOC 1
Ground Time Overcurrent 1 has picked up
Ground Time Overcurrent 1 has operated
Ground Time Overcurrent 1 has dropped out
Same set of operands as shown for GROUND TOC1
Non-Volatile Latch 1 is ON (Logic = 1)
Non-Voltage Latch 1 is OFF (Logic = 0)
Non-Volatile Latch 16 is ON (Logic = 1)
Non-Voltage Latch 16 is OFF (Logic = 0)
Stage 1 of the Loss of Excitation element has picked up
Stage 2 of the Loss of Excitation element has picked up
Stage 1 of the Loss of Excitation element has dropped out
Stage 2 of the Loss of Excitation element has dropped out
Stage 1 of the Loss of Excitation element has operated
Stage 2 of the Loss of Excitation element has operated
The Loss of Excitation element has picked up
The Loss of Excitation element has dropped out
The Loss of Excitation element has operated
Negative Sequence Directional OC1 Forward has operated
Negative Sequence Directional OC1 Reverse has operated
Negative Sequence Directional OC2 Forward has operated
Negative Sequence Directional OC2 Reverse has operated
Negative Sequence Overvoltage element has picked up
Negative Sequence Overvoltage element has dropped out
Negative Sequence Overvoltage element has operated
Neutral Instantaneous Overcurrent 1 has picked up
Neutral Instantaneous Overcurrent 1 has operated
Neutral Instantaneous Overcurrent 1 has dropped out
Same set of operands as shown for NEUTRAL IOC1
Neutral Overvoltage element has picked up
Neutral Overvoltage element has dropped out
Neutral Overvoltage element has operated
Neutral Time Overcurrent 1 has picked up
Neutral Time Overcurrent 1 has operated
Neutral Time Overcurrent 1 has dropped out
Neutral Directional OC1 Forward has operated
Neutral Directional OC1 Reverse has operated
Same set of operands as shown for NTRL DIR OC1
Overfrequency 1 has picked up
Overfrequency 1 has operated
Overfrequency 1 has dropped out
Same set of operands as shown for OVERFREQ 1
G60 Generator Management Relay