B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 13 of 40)
ADDR
REGISTER NAME
4C60
...Repeated for User-Definable Display 4
4C80
...Repeated for User-Definable Display 5
4CA0
...Repeated for User-Definable Display 6
4CC0
...Repeated for User-Definable Display 7
4CE0
...Repeated for User-Definable Display 8
B
4D00
...Repeated for User-Definable Display 9
4D20
...Repeated for User-Definable Display 10
4D40
...Repeated for User-Definable Display 11
4D60
...Repeated for User-Definable Display 12
4D80
...Repeated for User-Definable Display 13
4DA0
...Repeated for User-Definable Display 14
4DC0
...Repeated for User-Definable Display 15
4DE0
...Repeated for User-Definable Display 16
User Programmable Pushbuttons (Read/Write Setting) (12 modules)
4E00
User Programmable Pushbutton 1 Function
4E01
User Programmable Pushbutton 1 Top Line
4E0B
User Programmable Pushbutton 1 On Text
4E15
User Programmable Pushbutton 1 Off Text
4E1F
User Programmable Pushbutton 1 Drop-Out Time
4E20
User Programmable Pushbutton 1 Target
4E21
User Programmable Pushbutton 1 Events
4E22
User Programmable Pushbutton 1 Reserved (2 items)
4E24
...Repeated for User Programmable Pushbutton 2
4E48
...Repeated for User Programmable Pushbutton 3
4E6C
...Repeated for User Programmable Pushbutton 4
4E90
...Repeated for User Programmable Pushbutton 5
4EB4
...Repeated for User Programmable Pushbutton 6
4ED8
...Repeated for User Programmable Pushbutton 7
4EFC
...Repeated for User Programmable Pushbutton 8
4F20
...Repeated for User Programmable Pushbutton 9
4F44
...Repeated for User Programmable Pushbutton 10
4F68
...Repeated for User Programmable Pushbutton 11
4F8C
...Repeated for User Programmable Pushbutton 12
Flexlogic (Read/Write Setting)
5000
FlexLogic™ Entry (512 items)
Flexlogic Timers (Read/Write Setting) (32 modules)
5800
FlexLogic™ Timer 1 Type
5801
FlexLogic™ Timer 1 Pickup Delay
5802
FlexLogic™ Timer 1 Dropout Delay
5803
Reserved (5 items)
5808
...Repeated for FlexLogic™ Timer 2
5810
...Repeated for FlexLogic™ Timer 3
5818
...Repeated for FlexLogic™ Timer 4
5820
...Repeated for FlexLogic™ Timer 5
5828
...Repeated for FlexLogic™ Timer 6
5830
...Repeated for FlexLogic™ Timer 7
5838
...Repeated for FlexLogic™ Timer 8
5840
...Repeated for FlexLogic™ Timer 9
5848
...Repeated for FlexLogic™ Timer 10
5850
...Repeated for FlexLogic™ Timer 11
5858
...Repeated for FlexLogic™ Timer 12
5860
...Repeated for FlexLogic™ Timer 13
5868
...Repeated for FlexLogic™ Timer 14
5870
...Repeated for FlexLogic™ Timer 15
B-20
RANGE
0 to 2
---
---
---
0 to 60
0 to 2
0 to 1
0 to 65535
0 to 65535
0 to 2
0 to 60000
0 to 60000
0 to 65535
G60 Generator Management Relay
APPENDIX B
UNITS
STEP
FORMAT
---
1
F109
---
---
F202
---
---
F202
---
---
F202
s
0.05
F001
---
1
F109
---
1
F102
---
1
F001
---
1
F300
---
1
F129
---
1
F001
---
1
F001
---
1
F001
DEFAULT
2 (Disabled)
(none)
(none)
(none)
0
0 (Self-reset)
0 (Disabled)
0
16384
0 (millisecond)
0
0
0
GE Multilin