GE G60 Instruction Manual page 135

Generator management relay
Hide thumbs Also See for G60:
Table of Contents

Advertisement

5 SETTINGS
The operands available for this relay are listed alphabetically by types in the following table.
Table 5–5: G60 FLEXLOGIC™ OPERANDS (Sheet 1 of 6)
OPERAND TYPE
OPERAND SYNTAX
CONTROL
CONTROL PUSHBTN n ON
PUSHBUTTONS
DIRECT DEVICES
DIRECT DEVICE 1On
DIRECT DEVICE 16On
DIRECT DEVICE 1Off
DIRECT DEVICE 16Off
DIRECT INPUT/
DIR IO CH1(2) CRC ALARM
OUTPUT
CHANNEL
DIR IO CRC ALARM
MONITORING
DIR IO CH1(2) UNRET ALM
DIR IO UNRET ALM
ELEMENT:
100% STATOR STG1 PKP
100% Stator Ground
100% STATOR STG1 OP
100% STATOR STG1 DPO
100% STATOR STG2 PKP
100% STATOR STG2 OP
100% STATOR STG2 DPO
100% STATOR PKP
100% STATOR OP
100% STATOR DPO
ELEMENT:
3RD HARM NTRL UV PKP
3rd Harmonic
3RD HARM NTRL UV OP
Neutral Undervoltage
3RD HARM NTRL UV DPO
ELEMENT:
ACCDNT ENRG ARMED
Accidental
ACCDNT ENRG DPO
Energization
ACCDNT ENRG OP
ELEMENT:
AUX OV1 PKP
Auxiliary
AUX OV1 DPO
Overvoltage
AUX OV1 OP
ELEMENT:
AUX UV1 PKP
Auxiliary
AUX UV1 DPO
Undervoltage
AUX UV1 OP
ELEMENT:
Counter 1 HI
Digital Counters
Counter 1 EQL
Counter 1 LO
Counter 8 HI
Counter 8 EQL
Counter 8 LO
ELEMENT:
Dig Element 1 PKP
Digital Elements
Dig Element 1 OP
Dig Element 1 DPO
Dig Element 16 PKP
Dig Element 16 OP
Dig Element 16 DPO
ELEMENT:
DIR POWER 1 STG1 PKP
Sensitive Directional
DIR POWER 1 STG2 PKP
Power
DIR POWER 1 STG1 DPO
DIR POWER 1 STG2 DPO
DIR POWER 1 STG1 OP
DIR POWER 1 STG2 OP
DIR POWER 1 PKP
DIR POWER 1 DPO
DIR POWER 1 OP
DIR POWER 2
ELEMENT
FREQ RATE n PKP
Frequency Rate of
FREQ RATE n DPO
Change
FREQ RATE n OP
GE Multilin
OPERAND DESCRIPTION
Control Pushbutton n (n = 1 to 7) is being pressed.
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
The rate of Direct Input messages received on Channel 1(2) and failing the
CRC exceeded the user-specified level.
The rate of Direct Input messages failing the CRC exceeded the user-
specified level on Channel 1 or 2.
The rate of returned direct input/output messages on Channel 1(2) exceeded
the user-specified level (ring configurations only).
The rate of returned direct input/output messages exceeded the user-
specified level on Channel 1 or 2 (ring configurations only).
Stage 1 of the 100% Stator Ground element has picked up
Stage 1 of the 100% Stator Ground element has operated
Stage 1 of the 100% Stator Ground element has dropped out
Stage 2 of the 100% Stator Ground element has picked up
Stage 2 of the 100% Stator Ground element has operated
Stage 2 of the 100% Stator Ground element has dropped out
The 100% Stator Ground element has picked up
The 100% Stator Ground element has operated
The 100% Stator Ground element has dropped out
Third Harmonic Neutral Undervoltage element has picked up
Third Harmonic Neutral Undervoltage element has operated
Third Harmonic Neutral Undervoltage element has dropped out
The Accidental Energization element is armed.
The Accidental Energization element has dropped out.
The Accidental Energization element has operated.
Auxiliary Overvoltage element has picked up
Auxiliary Overvoltage element has dropped out
Auxiliary Overvoltage element has operated
Auxiliary Undervoltage element has picked up
Auxiliary Undervoltage element has dropped out
Auxiliary Undervoltage element has operated
Digital Counter 1 output is 'more than' comparison value
Digital Counter 1 output is 'equal to' comparison value
Digital Counter 1 output is 'less than' comparison value
Digital Counter 8 output is 'more than' comparison value
Digital Counter 8 output is 'equal to' comparison value
Digital Counter 8 output is 'less than' comparison value
Digital Element 1 is picked up
Digital Element 1 is operated
Digital Element 1 is dropped out
Digital Element 16 is picked up
Digital Element 16 is operated
Digital Element 16 is dropped out
Stage 1 of the Directional Power element 1 has picked up
Stage 2 of the Directional Power element 1 has picked up
Stage 1 of the Directional Power element 1 has dropped out
Stage 2 of the Directional Power element 1 has dropped out
Stage 1 of the Directional Power element 1 has operated
Stage 2 of the Directional Power element 1 has operated
The Directional Power element has picked up
The Directional Power element has dropped out
The Directional Power element has operated
Same set of operands as DIR POWER 1
The n-th Frequency Rate of Change element has picked up
The n-th Frequency Rate of Change element has dropped out
The n-th Frequency Rate of Change element has operated
G60 Generator Management Relay
5.4 FLEXLOGIC™
5
5-53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ur series

Table of Contents