Parameter
Menu 12
structure
Input 1
Input 2
(Pr 12.08, Pr 12.28)
(Pr 12.09, Pr 12.29)
High
High
High
Low
Low
High
Low
Low
* For more information on Oht4.P and PH.P trips, and SPMC see Unidrive SPM User Guide.
5.14.1
Brake control function
The brake control function can be used to control an electro-mechanical brake via the drive digital I/O.
Figure 5-13 Brake function
Drive active
10.02
Reference
on
1.11
Speed
feedback
3.02
Brake apply
speed
12.45
162
Keypad and
Parameter x.00
display
description format
State
OK
Over temperature
Phase loss
Mains Loss
OR
Brake apply
12.46
speed delay
+
_
Key
Input
0.XX
terminals
Output
0.XX
terminals
www.controltechniques.com
Parameter
Advanced parameter
descriptions
Output
Trip
(Pr 12.12, Pr 12.32)
None
0%
Oht4.P trip*
100%
PH.P trip*
100%
None
100%
Enable position
controller during
brake release
Post-brake
release delay
Brake
controller
12.41
enable
T25 digital
8.12
I/O 2 invert
Relay source
8.17
invert
T25 digital I/O 2
8.22
source / destination
Relay source
8.27
T25 digital I/O 2
8.32
output select
Read-write (RW)
parameter
Read-only (RO)
parameter
Serial comms
Electronic
protocol
nameplate
13.10
12.49
12.47
2.03
12.40
Brake apply
12.48
delay
6.08
input
output
i
o
LAT
reset
r
If the reset input is 1, the output is 0.
If the reset input is 0, the output latches
at 1 if the input is 1.
Digitax ST Advanced User Guide
Issue Number: 1
Performance
Position
control
mode
( = 1)
Ramp
hold
Brake
release
Hold zero
speed
Need help?
Do you have a question about the Digitax ST and is the answer not in the manual?
Questions and answers