Control Techniques Digitax ST Advanced User's Manual page 103

Ac variable speed drive for servo motors
Table of Contents

Advertisement

Parameter
Keypad and
Parameter x.00
structure
display
Parameter value
Parameter string
0
1
2
3
4
5
6
In modes 2 and 4 the destination parameter is at a value equivalent to 0.0% when the input current is less than 4mA. In modes 3 and 5 the destination
parameter is at a value equivalent to 100.0% when the input current is less than 4mA.
7.12
T7 analog input 2 scaling
Bit
SP
Coding
Range
0.000 to 4.000
Default
1.000
Update rate
Background read
7.13
T7 analog input 2 invert
Bit
SP
Coding
1
Default
0
Update rate
Background read
7.14
T7 analog input 2 destination
Bit
SP
Coding
Range
Pr 0.00 to Pr 21.51
Default
Pr 1.37
Update rate
Read on drive reset
7.15
T8 analog input 3 mode
Bit
SP
Coding
Range
0 to 9
Default
8
Update rate
Background read
The following modes are available for the analog input 3. In modes 2 and 3 a current loop loss trip is generated if the input current falls below 3mA.
Parameter value
Parameter string
0
1
2
4-20.tr
3
20-4.tr
4
5
6
7
8
9
th.diSp
Digitax ST Advanced User Guide
Issue Number: 1
Parameter
description format
0-20
20-0
4-20.tr
4 -20mA with trip on loss
20-4.tr
20 - 4mA with trip on loss
4-20
4 - 20mA with no trip on loss
20-4
20 - 4mA with no trip on loss
VOLt
FI
DE
Txt VM DP
ND
3
FI
DE
Txt VM DP
ND
FI
DE
Txt
VM
DP
ND
1
2
FI
DE
Txt VM DP
ND
1
0-20
20-0
4 -20mA with trip on loss
20 - 4mA with trip on loss
4-20
4 - 20mA with no trip on loss
20-4
20 - 4mA with no trip on loss
VOLt
th.SC
Thermistor with short circuit detection
th
Thermistor without short circuit detection
Thermistor display only with no trip
www.controltechniques.com
Advanced parameter
Serial comms
descriptions
protocol
Mode
0 - 20mA
20 - 0mA
Voltage mode
RA
NC
NV
PT
US RW BU
1
RA
NC
NV
PT
US RW BU
1
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
Mode
0 - 20mA
20 - 0mA
Voltage mode
Electronic
Performance
nameplate
Comments
Trip if I < 3mA, Pr 7.02 = 0.0% if I < 4mA
Trip if I < 3mA, Pr 7.02 = 100.0% if I < 4mA
Pr 7.02 = 0.0% if I < 4mA
Pr 7.02 = 100.0% if I < 4mA
PS
1
1
PS
1
PS
1
1
PS
1
1
Comments
Trip if I < 3mA, Pr 7.03 = 0.0% if I < 4mA
Trip if I < 3mA, Pr 7.03 = 100.0% if I < 4mA
Pr 7.03 = 0.0% if I < 4mA
Pr 7.03 = 100.0% if I < 4mA
TH trip if R > 3k3
TH reset if R < 1k8
THS trip if R < 50R
TH trip if R > 3k3
TH reset if R < 1k8
Menu 7
103

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Digitax ST and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF