Sm-Keypad Plus - Control Techniques Digitax ST Advanced User's Manual

Ac variable speed drive for servo motors
Table of Contents

Advertisement

Parameter
Keypad and
structure
display
longer the key is held, until such time that the parameters maximum or
minimum is reached. However with the second method an increasing
rate of change does not take place when adjusting any other digit other
than the least significant digit since a digit can only have one of 10
different values. Holding the Up or Down will cause an auto repeat and
roll over to more significant digits but the rate of change is unaltered. If
the maximum or minimum is exceeded when adjusting any other digit
than the least significant one, the maximum value will flash on the
display to warn the user that the maximum or minimum has been
reached. If the user releases the Up or Down key before the flashing
stops the last in range value will re-appear on the display. If the Up or
Down key is held the display will stop flashing after 3 seconds and the
maximum value will be written to the parameter.
Table 2-1 Menu 40 parameter descriptions
Parameter
40.00 Parameter 0
40.01 Language selection
40.02 Software version
40.03 Save to flash
40.04 LCD contrast
Drive and attribute database upload was
40.05
bypassed
40.06 Browsing favourites control
40.07 Keypad security code
40.08 Communication channel selection
40.09 Hardware key code
40.10 Drive node ID (Address)
40.11
Flash ROM memory size
40.19 String database version number
40.20 Screen saver strings and enable
40.21 Screen saver interval
40.22 Turbo browse time interval
Table 2-2 Menu 41 parameter descriptions
Parameter
41.00 Parameter 0
41.01
to
Browsing filter source F01 to F50
41.50
41.51 Browsing favourites control
RW
Read / Write
Bit
Bit parameter
NC
Not copied
PS
Power down save
For more information about the SM-Keypad Plus, see the SM-Keypad Plus User Guide.
10
Parameter description
Parameter x.00
format
Range( )
0 to 32767
English (0), Custom (1),
French (2), German (3),
Spanish (4), Italian (5)
999999
Idle (0), Save (1), Restore (2),
Default (3)
0 to 31
Updated (0), Bypass (1)
Normal (0), Filter (1)
0 to 999
Disable (0), Slot1 (1), Slot2 (2),
Slot3 (3), Slave (4), Direct (5)
0 to 999
0 to 255
4Mbit (0), 8Mbit (1)
0 to 999999
None (0), Default (1), User (2)
0 to 600
0 to 200ms
Range( )
0 to 32767
Pr 0.00 to Pr 391.51
Normal (0), Filter (1)
RO
Read only
Txt
Text string
RA
Rating dependent
www.controltechniques.com
Advanced parameter
Serial comms
descriptions
protocol
Parameters can be set to 0 by pressing the Up and Down keys
simultaneously.
2.6

SM-Keypad Plus

All SM-Keypad Plus displays built after data code N10 have software
version 4.02.00 programmed and support 5 languages (English, French,
German, Spanish and Italian) in addition to a user defined parameter set.
This software also gives the user access to two menus for SM-Keypad
Plus. Menu 40 is for SM-Keypad Plus set up, menu 41 selects commonly
used parameters for quick browsing.
Keypads built prior to N10 only support one user defined extra
parameter set only.
The SM-Keypad Plus contains two menus, menu 40 and menu 41. The
parameters in these menus are listed below.
Default( )
0
English (0)
Idle (0)
16
Normal (0)
0
Disable (0)
0
1
Default (1)
120
50ms
Default( )
0
0
Normal (0)
Uni
Unipolar
FI
Filtered
PT
Protected
Electronic
Performance
nameplate
Type
RW Uni
RW Txt
RO Uni
PT
RW Txt
RW Uni
RO Txt
PT
RW Txt
RW Uni
RW Txt
RW Uni
RW Uni
RO Txt
PT US
RO Uni
PT
RW Txt
RW Uni
RW Uni
Type
RW Uni
RW Uni
RW Txt
Bi
Bi-polar
DE
Destination
US
User save
Digitax ST Advanced User Guide
Issue Number: 1
US
US
US
US
US
US
US
US
US

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Digitax ST and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents

Save PDF