4. Replacement and Adjustment
- Check the changed SP value on the SMC which was output in step 2 and set it manually.
Especially, ensure that the values of the following SPs are same as the setting before the
replacement.
- a. SP5-045-001 (Accounting counter: Counter Method)
- b. SP5-302-002 (Set Time: Time Difference)
• Because the PM counters have been reset during NV-RAM replacement, it is necessary to replace
all the PM parts for proper PM management.
• If a message tells you need a SD card to restore displays after the NV-RAM replacement, create a
"SD card for restoration" and restore with the SD card.
SP descriptions
• 5-846-051 (UCS Setting: Backup All Addr Book)
Uploads all directory information to the SD card.
• SP5-748-101 (OpePanel Setting: Op Type Action Setting)
Sets the operation panel type.
0: Normal operation panel
1: Smart operation panel
• SP5-748-201 (OpePanel Setting: Cheetah Panel Connect Setting)
0: OFF
1: ON
• SP5-752-001 (Copy: FlairAPIFunction Setting)
Sets Copy FlairAPI Function enable / disable.
• SP1-041-001 (Scan: FlairAPI Setting)
Sets Scanner FlairAPI Function enable / disable.
• SP3-301-001 (FAX: FlairAPI Setting)
Sets Fax FlairAPI Function enable / disable.
Bit Switches for FlairAPI Settings
Bit
Item
Flair API Server
0
Boot
696
0
1
Specifies whether to start the HTTP server
for Flair API.
Enabl
Disabled
ed
"0" disables all the Flair API functions
(Remote UI).
Description
Initial
value
0