2. If TM/ID sensor is contaminated, clean it (never use a dry cloth).
3. Execute SP5-804-255(OUTPUT Check: Paper Transfer Contact Operation) to operate the Paper
Transfer Contact Motor to check opening/closing of the shutter.
4. Check if there is an abnormality on the image transfer belt surface.
5. If any abnormalities are found on the image transfer belt surface, replace the image transfer belt.
• Belt scratched
• Belt corrugation, belt skew
• Cleaning failure
• Background stains
• Filming
6. Check the TM/ID sensor for malfunctions, and recover or replace it if there are any defects.
7. Check the harness. Replace the harness if it is disconnected, or damaged.
8. If the SC is not cleared even after performing steps 1 to 6, replace the BCU

Recovery Check Procedure

1. Execute Vsg adjustment.
2. Execute SP3-323-001(Vsg Adj OK?: Latest) to check the code.
• If code is "1": Recovered
• If code is not "1": Not recovered

Adjustment after Recovery

After performing recovery on SC370, execute the following adjustment procedures.
1. Execute SP2-111-004 (Forced Line Position: Adj. Mode d).
2. Execute the following SPs and check the results:
• SP2-194-007 (Execution Result)
• SP2-194-010 (Error Result: C)
• SP2-194-011 (Error Result: M)
• SP2-194-012 (Error Result: Y)
Execute result sample
Factory default: 0
Success: 1
3. Execute SP3-011-011 (Manual ProCon :Exe).
4. Execute the following SPs and check the results.
Troubleshooting for SC Errors