Early Tray Full Detection Mylar For Internal Finisher Sr3130 (D690); Pasting The Mylar - Ricoh MP C3004 Field Service Manual

Hide thumbs Also See for MP C3004:
Table of Contents

Advertisement

Cause
Depending on the type of paper or the manufacturer, the paper may not be the correct size. In this
case, the paper may not align properly even when the jogger is used.
Solution
Adjust the jogger width with SP6-143 (adjustable threshold: -1.5 to +1.5 mm for each paper size).
• SP6-143 (Jogger Pos Adj:1K FIN)
• Adjust the jogger width to be slightly narrower (approximately -0.5 mm) than the paper width.

Early Tray Full Detection Mylar for Internal Finisher SR3130 (D690)

Paper curl may occur when output gets to near full. Paste the Mylar to the full detection feeler to detect
tray full early before paper curl occurs.

Pasting the Mylar

1.
Pull the finisher [A]
Troubleshooting for Finishing Options
1143

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c4504Mp c3504Mp c5504Mp c6004

Table of Contents