6. Troubleshooting
Others
If the error occurs periodically, do the following steps. If the result is as shown in the "Problem
Judgement" column, follow the solutions.
"Replace the waste toner bottle" is displayed even when it is clear that the waste
toner bottle is not full
Target Part/SP No.: Waste Toner Bottle Full Sensor / SP5-803-032 (Toner Collection Full
Sensor)
Execute an INPUT check with no feeler in the sensor detection range
(Done after detaching the waste toner bottle)
Solution:
• Clean the sensor.
• Reconnect the connector.
• Replace the sensor.
• Replace the Imaging IOB.
• Replace the harness.
Waste toner bottle is never full
Target Part/SP No.: Waste Toner Bottle Full Sensor / SP5-803-032 (Toner Collection Full
Sensor)
Execute an INPUT check with feeler within the sensor detection range (Done
after removing the waste toner bottle)
Solution:
• Clean the sensor.
• Reconnect the connector.
• Replace the sensor.
• Replace the Imaging IOB.
• Replace the harness.
1134
Cause verification
Cause verification
Problem Judgement
1: Full
Problem Judgement
0: Not full